3
Features
T
Features
3-171
T
ime-Out, Variable
Description
Provides timers to control various features or functions.
The following timers are programmable:
System Timer Items
Range
Automatic Redial Interval Time
n
✕
10 s, n: 3 – 120
Automatic Redial Repeated Times
1 – 12 times
Call Forwarding – No Answer Time-Out
1 – 12 rings
CO Dial Starting Time
n
✕
100 ms, n: 0 – 40
Doorphone-to-CO Line Call Duration Time
0 – 300 s
Extension-to-CO Call Duration Time
1 – 64 min
Hold Recall Time
0 – 240 s
Intercept Routing Time-Out
3 – 48 rings
Message Waiting Ring Interval Time
0 – 64 min
Outgoing Message Duration Time
0 / 16 / 32 / 64 s
Pickup Dialling Waiting Time
0 – 8 s
Ring-Off Detection Time
6 / 11 s
SMDR Duration Count Starting Time
0 – 60 s
Timed Reminder Alarm Ring Time
30 – 240 s
Toll Restriction First Digit Time-Out
5 – 120 s
Toll Restriction Inter-digit Time-Out
5 – 30 s
Transfer Recall Time
3 – 48 rings
CO Line Group Timer Items
Disconnect Time
0.5 / 2.0 / 4.0 s
Register Recall Signal Time
Disable / 80 / 96 / 112 /
200 / 300 / 400 / 500 /
600 / 700 / 800 / 900 /
1000 / 1100 / 1200 ms
Pause Time
1.5 / 2.5 / 3.5 / 4.5 / 5.5
/ 6.5 s
CO Line Timer Items
CPC Signal Detection Time (Incoming)
n
✕
8 ms, n: 02 – 75
DTMF Digit Time
96 / 160 ms
Extension Timer Items
Delayed Ringing Count
Disable / Immediate /
2 / 4 / 6 / 8 rings /
No ring
Summary of Contents for KX-TD1232E
Page 95: ...2 51 8 Blank ...
Page 102: ......
Page 309: ...4 11 2 Blank ...
Page 324: ...4 24 2 Blank ...
Page 352: ...4 42 2 Blank ...
Page 393: ...4 69 14 Blank ...
Page 411: ...4 83 4 Blank ...
Page 492: ...4 142 8 Blank ...
Page 494: ...4 144 Blank ...
Page 532: ......
Page 533: ...Section 5 List This section lists tone ring tone and default values of system programming ...
Page 631: ......