8.2.4
Installing the Unit
8-14
DECT Portable Station Section
8.2.4
Installing the Unit
6. Wireless Extension Connection
Use a Cell Station Cord (4-conductor wiring – included) and 4-pin plug (included) to connect
the cell station line. There are 2 plugs for the KX-TD144 and 6 plugs for the KX-TD146 to
connect the Cell Stations.
Maximum length of the cable: AWG 24 (ø 0.6 mm): Under 1 km
6-1. Insert the wires of the 4-conductor wiring cord into the holes
in the plug to connect pins “D1”, “D2”, “V1” and “V2”.
D1: Data 1
V1: V
D2: Data 2
V2: Voltage –
Press the transparent part into the black part.
Insert the other end of the wires into the modular plug.
Note: Do not peel off the wire coating. Insert the wires all the way.
6-2. Insert the 4-pin plug into a cell station jack on the unit, and
attach the ferrite core (included) to the plug cord.
D1
V1
V2
D2
D1
V1
V2
D2
1
2
4-pin plug
Modular plug
Panasonic
6
1
CS
no.
D1
V1
V2
D2
2
3
4
5
CS INF
6CS
Panasonic
CS INF
2
1
CS
no.
D1
V1
V2
D2
5 cm
To the Cell Station
Ferrite Core
Roll the cord once around
the ferrite core and close
the core.
Note: Put it in the cabinet
when closing the cabinet cover.
Connect the ground terminal to ground.
Note: If other expansion units are
installed, the frame ground connection
is required for only one unit.
KX-TD144
KX-TD146
Summary of Contents for KX-TD1232E
Page 95: ...2 51 8 Blank ...
Page 102: ......
Page 309: ...4 11 2 Blank ...
Page 324: ...4 24 2 Blank ...
Page 352: ...4 42 2 Blank ...
Page 393: ...4 69 14 Blank ...
Page 411: ...4 83 4 Blank ...
Page 492: ...4 142 8 Blank ...
Page 494: ...4 144 Blank ...
Page 532: ......
Page 533: ...Section 5 List This section lists tone ring tone and default values of system programming ...
Page 631: ......