25
System Programming
TIE First / Inter Digit Time
220
Description
Assigns the maximum time allowed between the start of the dial
tone and the first digit dialled (First Digit Time), and between digits
(Inter Digit Time) on a TIE call. If an extension user fails to dial
any digits during this time, the DTMF receiver is released. This
timer applies until the Toll Restriction check is completed.
Selection
Time (seconds): 3 to 30
Default
5 s
Programming
1.
Enter 220.
Display: TIE Timer
2.
Press NEXT.
Display example: Time:5 sec
3.
Enter the time.
To change the current entry, press CLEAR and enter the new time.
4.
Press STORE.
5.
Press END.
Conditions
• This timer is used for toll restriction checking.
• You cannot leave the entry empty.
Feature References
Section 3, Features
Toll Restriction