4.6
CO Line Programming
CPC Signal Detection Incoming Set
405
System Programming
4-93
Description
Assigns the expected minimum duration of the CPC Signal on
incoming outside calls. If this is programmed, the system
disconnects the line when the CPC Signal is detected.
Selection
• CO line number:
KX-TD816 – 01 through 08,
(
=all CO lines)
KX-TD1232 – 01 through 24,
(
=all CO lines)
• Time (milliseconds): Disable (no detection) / 02 through 75 (
✕
8
is the actual time)
(See the table on the following page.)
Default
All CO lines – 44 (352 ms)
Programming
1.
Enter 405.
Display : CPC Detection
2.
Press NEXT.
Display: CO Line NO?–>
3.
Enter a CO line number.
To enter CO line number 01, you can also press NEXT.
Display example: CO01:Disable
4.
Enter the time, or press CLEAR to select “Disable.”
To change the current entry, press CLEAR and the new time.
5.
Press STORE.
6.
To program another CO line, press NEXT or PREV, or
SELECT and the desired CO line number.
7.
Repeat steps 4 through 6.
8.
Press END.
Conditions
• In the case of KX-TD1232, CO01 through CO12 are for the Master
System and CO13 through CO24 are for the Slave, if available.
• To assign all CO lines to one selection, press the
key at step 3. In
this case, the display shows the contents programmed for CO01.
• You may disable CPC Signal Detection for a CO line.
• Program [415] “CPC Signal Detection Outgoing Set” is used to
program CPC Signal Detection for outgoing outside calls.
Feature References
Section 3, Features,
Calling Party Control (CPC) Signal Detection
Summary of Contents for KX-TD1232E
Page 95: ...2 51 8 Blank ...
Page 102: ......
Page 309: ...4 11 2 Blank ...
Page 324: ...4 24 2 Blank ...
Page 352: ...4 42 2 Blank ...
Page 393: ...4 69 14 Blank ...
Page 411: ...4 83 4 Blank ...
Page 492: ...4 142 8 Blank ...
Page 494: ...4 144 Blank ...
Page 532: ......
Page 533: ...Section 5 List This section lists tone ring tone and default values of system programming ...
Page 631: ......