4.10
Resource Programming
TD197 Baud Rate Set
817
4-167.1
System Programming
Description
Assigns the KX-TD197 modem standard. There are two standards
available – BELL and CCITT-V.34.
Selection
• Master / Slave
• BELL / V.34-9600 / V.34-14400 / V.34-19200 / V.34-28800 /
V.34-33600
Default
Master and Slave – V.34-33600
Programming
1.
Enter 817.
Display: TD197 Type
2.
Press NEXT.
Display example: Mast.:V.34-33600
3.
Keep pressing SELECT until the desired selection is
displayed.
4.
Press NEXT.
Display example: Slave:V.34-33600
5.
Keep pressing SELECT until the desired selection is
displayed.
6.
Press STORE.
7.
Press END.
Conditions
• Normally, if V.34-33600 is selected, the modem’s transmission is as fast
as possible. However, if the line quality is not good and causes many
errors, please select the lower speed standard.
Feature References
Section 3, Features,
System Programming and Diagnosis with Personal Computer