3
Features
S
Features
3-169
S
ystem Working Report
Description
The Digital Super Hybrid System automatically records the
system’s working state. A printer connected to the EIA (RS-232C)
port can be used to print the recorded data.
Recorded contents are as follows:
1. Date of record
• The date and time when cleared
• The date and time when printed out
2. Incoming calls
• The number of incoming calls
• The number of answered incoming calls
• The number of unanswered incoming calls
• The ratio of the answered calls to the incoming calls
Number of answered calls
✕
100 (%)
Number of incoming calls
• The average time from receipt of call to answer of the
incoming and answered calls
• The average duration time of talk of the answered calls
3. Outgoing calls
• The number of access requested
• The number of access succeeded
• The number of access failed
• The ratio of access succeeded
Number of access succeeded
✕
100 (%)
Number of access requested
• The average duration of the dialled calls
These records can be deleted by the manager and the operator, and
new data will be recorded thereafter.
Conditions
Connect a printer to the EIA (RS-232C) connector located on the main
unit. After connecting a printer, do not press the RETURN key, if
provided on the printer, in 10 seconds.
Connection References
Section 2, Installation
2.3.7 Printer Connection
Summary of Contents for KX-TD1232E
Page 95: ...2 51 8 Blank ...
Page 102: ......
Page 309: ...4 11 2 Blank ...
Page 324: ...4 24 2 Blank ...
Page 352: ...4 42 2 Blank ...
Page 393: ...4 69 14 Blank ...
Page 411: ...4 83 4 Blank ...
Page 492: ...4 142 8 Blank ...
Page 494: ...4 144 Blank ...
Page 532: ......
Page 533: ...Section 5 List This section lists tone ring tone and default values of system programming ...
Page 631: ......