8.2.3
Location of the Unit
8-10
DECT Portable Station Section
8.2.3
Location of the Unit
KX-TD1232 with the KX-TD144
Up to two Cell Station Interface Units (KX-TD144) can be
installed to any of the three expansion areas on the KX-TD1232.
Up to two Cell Stations (KX-TD142) can be connected to the KX-
TD144.
Note
• System Programming is required for location identification. Refer to
program [109], “Expansion Card/Unit Type,” in Section 4.
Default : Area 1 = 4-CO Line Unit
Areas 2 and 3 = 8-Station Line Unit
Select “E1” or “E2” for the Cell Station Interface Unit (KX-TD144).
Both types are the same for an 8-Station Line Unit (KX-TD170).
• KX-TD144 and KX-TD142 can only be connected to the Master
System.
Panasonic
D1232
CS INF
DECT
DECT
KX-TD144
KX-TD142
Expansion Unit
Connectors
Remove the front cover
plate(s).
Expansion
area 3
Expansion
area 2
Expansion
area 1
Summary of Contents for KX-TD1232E