4.4
Timer Programming
Call Duration Count Start Time
212
System Programming
4-81
Description
Sets the number of seconds the system waits between the end of
dialling and the start of the SMDR timer for outgoing toll calls.
When the system has sent out all the digits to the central office and
this timer expires, the system starts counting the call. A display
telephone shows the elapsed time of the call. The starting time and
the duration of a call are recorded in the SMDR record.
Selection
Time (seconds): 0 through 60
Default
0 s
Programming
1.
Enter 212.
Display: SMDR Durat Time
2.
Press NEXT.
Display example: Time: 0 sec
3.
Enter the time.
To change the current entry, press CLEAR and the new time.
4.
Press STORE.
5.
Press END.
Conditions
• The timer starts counting after all the digits are dialled. This timer is
not applied to incoming calls. The timer for incoming calls starts
immediately.
• You cannot leave the entry empty.
Feature References
Section 3, Features,
Display, Call Information
Station Message Detail Recording (SMDR)
Summary of Contents for KX-TD1232E
Page 95: ...2 51 8 Blank ...
Page 102: ......
Page 309: ...4 11 2 Blank ...
Page 324: ...4 24 2 Blank ...
Page 352: ...4 42 2 Blank ...
Page 393: ...4 69 14 Blank ...
Page 411: ...4 83 4 Blank ...
Page 492: ...4 142 8 Blank ...
Page 494: ...4 144 Blank ...
Page 532: ......
Page 533: ...Section 5 List This section lists tone ring tone and default values of system programming ...