4.6
CO Line Programming
Reverse Circuit Assignment
416
System Programming
4-103
Description
Enables or disables to detect Reverse Circuit.
Selection
• CO line number:
KX-TD816 – 01 through 08,
(
=all CO lines)
KX-TD1232 – 01 through 24,
(
=all CO lines)
• Regular (no detection) / Reverse (detection)
Default
All CO lines – Regular
Programming
1.
Enter 416.
Display: Reverse Circuit
2.
Press NEXT.
Display: CO Line NO?–>
3.
Enter a CO line number.
To enter CO line number 01, you can also press NEXT.
Display example: CO01:Regular
4.
Keep pressing SELECT until the desired selection is
displayed.
5.
Press STORE.
6.
To program another CO line, press NEXT or PREV, or
SELECT and the desired CO line number.
7.
Repeat steps 4 through 6.
8.
Press END.
Conditions
To assign all CO lines to one selection, press the
key at step 3. In this
case, the display shows the contents programmed for CO01.
Feature References
Section 3, Features,
Reverse Circuit