4.10
Resource Programming
SMDR Incoming / Outgoing Call Log Printout
800
System Programming
4-157
Description
Used to determine which calls will produce an SMDR printout.
Selection
• Outgoing calls: All (all calls) / Toll (toll calls only) /
Off (no printing)
• Incoming calls: On (all calls) / Off (no printing)
Default
All calls – Off
Programming
1.
Enter 800.
Display: Duration Log
2.
Press NEXT to program outgoing calls.
Display: Outgoing:Off
3.
Keep pressing SELECT until the desired selection is
displayed.
4.
Press STORE.
5.
Press NEXT to program incoming calls.
Display: Incoming:Off
6.
Keep pressing SELECT until the desired selection is
displayed.
7.
Press STORE.
8.
Press END.
Conditions
• It is necessary to connect a printer to the EIA (RS-232C) port provided
on the system.
• After connecting a printer, do not press the RETURN key, if provided
on the printer, in 10 seconds. Otherwise, the usage of the EIA port is
changed to system programming and printout will not occur.
• If “Toll” is selected, the system will print out all the calls starting from
the numbers stored in programs [301]–[305] “TRS Denied Code Entry
for Levels 2 through 6.”
Feature References
Section 3, Features,
Station Message Detail Recording (SMDR)
Summary of Contents for KX-TD1232E
Page 95: ...2 51 8 Blank ...
Page 102: ......
Page 309: ...4 11 2 Blank ...
Page 324: ...4 24 2 Blank ...
Page 352: ...4 42 2 Blank ...
Page 393: ...4 69 14 Blank ...
Page 411: ...4 83 4 Blank ...
Page 492: ...4 142 8 Blank ...
Page 494: ...4 144 Blank ...
Page 532: ......
Page 533: ...Section 5 List This section lists tone ring tone and default values of system programming ...
Page 631: ......