Wireless Service Gateway WSGOpenScape WLAN Phone WL4/WL4 Plus
Installation Guide
A31003-M2000-J109-01-7631
Page 1: ...Wireless Service Gateway WSG OpenScape WLAN Phone WL4 WL4 Plus Installation Guide A31003 M2000 J109 01 7631...
Page 2: ...ify Software and Solutions GmbH Co KG 30 06 2020 All rights reserved Reference No A31003 M2000 J109 01 7631 The information provided in this document contains merely general descriptions or characteri...
Page 3: ...Connections 21 4 4 1 Ethernet Ports 21 4 4 2 Error Relay Output 21 4 4 3 Connection of AUX Inputs and AUX Outputs 22 4 5 Accessing Wireless Service Gateway WSG 22 4 5 1 Access via the Network 22 4 5...
Page 4: ...re 36 7 2 Restarting the Wireless Service Gateway WSG 37 7 2 1 Controlled Restart via the Restart Button 37 7 2 2 Forced Restart 37 7 3 Reset Back to Factory Default Settings 37 8 Troubleshooting Guid...
Page 5: ...con sumption Max 275 mA at 100 V AC input Max 1 A at 12 V DC input Delivery includes Wireless Service Gateway WSG hardware The Getting started and Safety document Wireless Service Gateway WSG EMBEDDED...
Page 6: ...guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be de termined by turning the equip...
Page 7: ...Canada This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la Classe B conforme la norme NMB 003 du Canada A31003 M2000 J109 01 7631 30 06 2020 Wireless Service G...
Page 8: ...nt with the default password changeme is used for administration and simple troubleshooting of the module The admin has permission to change all passwords except the sysadmin password The sysadmin acc...
Page 9: ...t can also be reached by pressing the Configuration button on the start page and then selecting Other Settings Advanced Con figuration All configurations can be set and changed on the Advanced Configu...
Page 10: ...rts for external temporary devices The rear side is used for connecting supply voltage communication to Ascom systems external systems inputs outputs etc Overview of Connectors Buttons and LEDs Figure...
Page 11: ...thernet Ports on page 21 LAN2 Currently not used for future releases V Ext GND Ext External 12 V power supply to provide galvanic isolation of the inputs and out puts see below In1 In2 and Out1 Out2 C...
Page 12: ...automatic startup 1 minute Warning T roubleshoot mode and during firmware upgrade Mass storage mode Yellow Yellow Power LED Red Red Blue also used if the Power parameter conflicts with the actual setu...
Page 13: ...anually by the user but if the module detects several major errors the module can place itself in Boot Mode Refer to chapter Message Distrib ution on page 29 Demonstration Mode Demonstration Mode make...
Page 14: ...ould be placed in a dry environment with a temperature range of 0 to 40 C Wall Mounting Four screws size 3 5 40 together with four wall plugs and four screws size M3 6 are deli vered with the product...
Page 15: ...vice Gate way WSG modules and one big bracket for one front mounted Wire less Service Gateway WSG module Reverse 19 rack kit Small left right brackets for two reverse mounted Wireless Service Gateway...
Page 16: ...e left side as shown in the figure below Figure 5 Mounting the assembly bracket 2 Fasten the assembly brackets in the rack see below screws not included Figure 6 Front mounted single in rack Front mou...
Page 17: ...nd on the bottom side as shown in the two figures below Figure 7 Front mounted double Figure 8 Front mounted double 2 Use the two small standard assembly brackets and fasten one on the right front sid...
Page 18: ...big assembly bracket on the right side of the module and the small assembly brackets on the left side as shown in the figure below Figure 10 Rear mounted single 2 Fasten the assembly brackets in the...
Page 19: ...ply Voltage Wireless Service Gateway WSG can be connected to an external power supply 12 24 V DC bat tery or power source as a complement to the primary power supply 100 240 V AC If the pri mary power...
Page 20: ...C screw connector 12 24VDC Figure 15 12 24 V DC connection to external power supply Change Power Supply parameter Wireless Service Gateway WSG is default configured to use the primary power supply 100...
Page 21: ...use the jack marked 2 is intended for future releases Shielded ethernet cables should be used for installation on trains to meet the regulatory re quirements for railway equipment Error Relay Output...
Page 22: ...Galvanic isolation of the inputs and outputs is provided by using a separate power supply If galvanic isolation is not needed and Wireless Service Gateway WSG is supplied by an exter nal 12 V power so...
Page 23: ...e Gateway WSG has not got a valid and unique IP address or when the IP address has been changed i e if Wireless Service Gate way WSG has been moved from one network to another It gives access to the m...
Page 24: ...e management port on the module The Found new hardware wizard opens but at this stage there is no valid port driver so close the wizard and continue to install the driver 2 Press the Mode button twice...
Page 25: ...ort Driver on Windows 7 When switching between mass storage mode and network mode it takes about 30 sec onds before the module can be accessed with the 192 5 36 229 address 1 Connect a mini USB type B...
Page 26: ...Panel Hardware and Sound 6 Select Device Manager under Devices and Printers Figure 23 RNDIS Ethernet gadget 7 Right click RNDIS Ethernet gadget and select Update driver software A new window opens 8...
Page 27: ...ucts set tings can be set in an installation Setup Wizard accessible from the web interface The Setup Wizard will start automatically the first time the module is accessed from the web browser and eve...
Page 28: ...in the menu and click the Reboot button 9 When Wireless Service Gateway WSG has been restarted enter the URL xxx xxx xxx xxx admin in your browser xxx xxx xxx xxx is the IP address that was given to W...
Page 29: ...ime The date and time format controls the appearance of date and time in log views and applica tion specific pages The administration pages that are common to all Wireless Service Gateway WSG will dis...
Page 30: ...ver xxx xxx xxx xxx EventHandler First the Alarm Management Server IP address is defined After the the application ser vice EventHandler is specified Working in Boot Mode If no application is running...
Page 31: ...inute until the status LED indicates starting up with quick flashing blue light then press the Mode button The Mode button LED will lit and show fixed blue light 3 Then wait until the status LED chang...
Page 32: ...tion date are shown If two versions have been installed information about both versions and also which ver sion that was last used by the module is shown The format of the installation date is depende...
Page 33: ...31 2 Select Software Install software 3 Click the Browse button and locate the software pkg file to install 4 Select where to save the software If two versions of the software already have been insta...
Page 34: ...n button in the Boot Mode GUI s upper right corner The Normal Operation dialogue box opens 2 Select which software to start and click OK 3 Select which settings to use for the software and click OK Th...
Page 35: ...light and by the Mode button LED with fixed blue light The module will automatically return to the previous license and parameters without restart af ter 2 hours Exiting before the 2 hours have passed...
Page 36: ...estart button by pressing the button and releasing it within 4 seconds The Status LED indicates shutting down with quick flashing blue light Before starting up again the Status LED will indicate waiti...
Page 37: ...not give you enough time to unplug the power cable Forced Restart Forced restart is used as a last resort when the module does not respond at all When a Forced restart is performed ongoing jobs are n...
Page 38: ...ve connected to or not correctly installed Note the installation differs be tween Windows XP Vista and Windows 7 Follow the instructions in chapter Access via the Management port on page 23 The PC has...
Page 39: ...ng an error to your supplier always include the ap propriate log file 1 Enter Boot Mode see Set the Module in Boot Mode on page 31 2 Click the Troubleshoot button 3 Click OK in the Troubleshoot dialog...