5-7
Section
"#
Address
Reference
page
Default
Setting range
Contents
No. of words
2028
3
X-axis interrupt input signal definition
0, 1
0
86
X-axis interrupt input signal type
0, 1
0
X-axis interrupt input emergency stop
parameter
0, 1
0
6028
Y-axis interrupt input signal definition
0, 1
0
Y-axis interrupt input signal classification
0, 1
0
Y-axis interrupt input emergency stop
parameter
0, 1
0
Note The addresses 6000 to 6028 are only for the NC211.
The following parameters can be set in pulses, millimeters, or inches.
•
Origin compensation (X address: 2007; Y address 6007)
•
Home shift (X address: 2010; Y address 6010)
•
CW limit (X address: 2011; Y address 6011)
•
CCW limit (X address: 2012; Y address 6012)
•
Zone 0 to zone 7 (X addresses: 2013 to 2020; Y addresses 6013 to 6020)
•
Reset present position setting (X address: 2022; Y address 6022)
The setting ranges for each of these parameters are shown in the following
table.
Item
Setting range
Origin compensation
(X address: 2007; Y address 6007)
0 to 999.9 mm
0 to 99.99 inch
Home shift
(X address: 2010; Y address 6010)
--9999.99 to 9999.99 mm
--999.999 to 999.999 inch
CW limit
(X address: 2011; Y address 6011)
0 to 9999.999 mm
0 to 999.9999 inch
CCW limit
(X address: 2012; Y address 6012)
0 to 9999.999 mm
0 to 999.9999 inch
Zone 0 to zone 7 (X addresses: 2013 to 2020;
Y addresses 6013 to 6020)
--9999.999 to 9999.999 mm
--999.9999 to 999.9999 inch
Reset present position setting
(X address: 2022; Y address 6022)
--9999.999 to 9999.999 mm
--999.9999 to 999.9999 inch
Note
1. The data unit (pulses, millimeters, inches) and pulse rate are set in parame-
ter addresses 2026 (X axis) and 6026 (Y axis).
2. The addresses 6007 to 6022 are only for the NC211.
5-7-1 Origin Return Speed Number (3 Words)
Axis
Address
X
2000
Y
6000 (NC211 only)
This parameter indirectly designates the speed address for when an origin re-
turn is executed on the X or Y axis. The setting is made in two digits, from 00 to
49. The indirectly designated addresses for both axes are as follows:
X axis: 4000 to 4049
Y axis: 8000 to 8049 (NC211 only)
For example, if “20” is set for the Y-axis origin return speed number, the origin
return will be executed at the speed registered at speed address 8020. For de-
tails on how to set speeds, refer to
5-4 Speeds
.
Data Unit Setting
(Pulse, Millimeter, Inch)
Addresses
Summary of Contents for SYSMAC C500-NC113
Page 1: ...Cat No W323 E3 1 Position Control Units SYSMAC C500 NC113 C500 NC211 OPERATION MANUAL...
Page 2: ...0 1 1 2 304 2 1 3 1 3 1 1 1...
Page 5: ...8 0...
Page 9: ...8 8 0 8...
Page 24: ...0 1...
Page 31: ...0 4 4 4 2 1 2 2...
Page 52: ...8 8 0...
Page 57: ...5 1 Section Acceleration Deceleration Pattern Edit Screen Dwell Time Data Edit Screen...
Page 107: ...0 00 C D 0 0 0 0 E 4 8 3 3 1 3 1 3 1 1 1...
Page 119: ...0 8 1 6...
Page 207: ...1 6 1 1 0 1 1 0 1 1 1 1 1 1 3 1 7 1 3 1 1 8 3...
Page 220: ...4 4 0 1 9 3...
Page 224: ...0 8 6 6...
Page 246: ...01 1 3 2 D 2 0 1 01 1 6 9 0 1 2 2 2 E 0 3 9 2 2 F H 69 9 2 4 54 60 7 5 2 I 4 2 7 2 3 2 69 0 2...
Page 247: ...J L 2 3 60 7 5 M N 2 0 1 6 9 2 O 2 2 2 2 5 91 2 5 6 4 2 2 2 P 0 0 87 87...
Page 248: ...2 2 2 2 9 4 2 0 R 7 6 0 4 9 6 9 0 6 9 0 6 9 S 2 2 2 2 6 6 2 A 2 B 2 2 69 0 3 3 3 2 T 9 4 2...
Page 249: ...W Z 2 2...