214685
249
Revision A
CAUTION
Check to be sure all bystanders have cleared the area.
NOTE:
If header float is set too light, it can prevent calibration of AHHC. You may need to set the float heavier for
calibration procedure so header doesn
’
t separate from the float module.
1.
Ensure center-link is set to
D
.
2.
Rest header on down stops, and unlock float.
3.
Put wings in locked position.
4.
Start the combine.
Figure 7.207: John Deere Combine Display
5.
Press the DIAGNOSTIC button (A) on the monitor. DIA
appears on the monitor.
6.
Press the CAL button (B). DIA-CAL appears on the
monitor.
Figure 7.208: John Deere Combine Display
7.
Press the UP or DOWN buttons until HDR appears on
the monitor.
8.
Press the ENTER button. HDR H-DN appears on the
monitor.
9.
Fully lower feeder house to the ground.
NOTE:
You may need to hold the HEADER DOWN switch for a
few seconds to ensure the feeder house is fully
lowered.