214685
175
Revision A
Figure 7.42: Case IH Combine Display
11. Locate AUTOTILT field (A).
•
If using a two-sensor system:
Select YES in the
AUTOTILT field.
•
If using a single-sensor system:
Select NO in the
AUTOTILT field.
Checking Voltage Range from Combine Cab (Case IH 5130/6130/7130; 5140/6140/7140)
NOTE:
Changes may have been made to combine controls or display since this document was published. Refer to the
combine operator
’
s manual for updates.
CAUTION
Check to be sure all bystanders have cleared the area.
1.
Position the header 150 mm (6 in.) above the ground, and unlock the float.
Figure 7.43: Float Lock
2.
Check that float lock linkage is on down stops
(washer [A] cannot be moved) at both locations.
NOTE:
If the header is not on down stops during the next two
steps, the voltage may go out of range during operation
causing a malfunction of the auto header height control
(AHHC) system. Refer to the header operator
’
s manual
for instructions on setting float.