214685
56
Revision A
4.2.11
Removing Feed Auger Fingers
DANGER
To avoid bodily injury or death from unexpected start-up or fall of a raised machine, always stop engine
and remove key before leaving the operator
’
s seat, and always engage safety props before going under
the machine for any reason.
Figure 4.57: Auger Access Hole Cover
1.
Remove bolts (A) and remove the access cover (B)
closest to the finger you are removing.
Figure 4.58: Auger Finger
2.
Remove hairpin (A), pull finger (B) out of finger
holder (C) from inside the auger, and then remove the
finger from the auger by pulling it out through plastic
guide (D).
Figure 4.59: Auger Finger Hole
3.
Remove the bolts (A) and tee nuts securing the plastic
guide (B) to the auger, and remove the guide from
inside the auger.