![MacDon FlexDraper FD1 Series Unloading And Assembly Instructions Download Page 173](http://html2.mh-extra.com/html/macdon/flexdraper-fd1-series/flexdraper-fd1-series_unloading-and-assembly-instructions_3353032173.webp)
214685
161
Revision A
Figure 7.10: Optional Two-Sensor Kit
–
Right Sensor
5.
Use a voltmeter to measure the voltage between the
ground (Pin 2) and signal (Pin 3) wires of the AHHC
sensor (A) at the back of the float module side frame.
Ensure it is at the high voltage limit for the combine.
Refer to Table
NOTE:
The wiring harness connector must be attached to the
sensor. Do
NOT
disconnect it.
6.
Repeat at the opposite side.
Figure 7.11: Float Indicator Box
7.
Fully lower the combine feeder house, and float the
header up off the down stops (float indicator [A] should
be at 4, and the float module should be fully separated
from the header).
NOTE:
You may need to hold the HEADER DOWN switch for a
few seconds to ensure the feeder house is fully
lowered.
Figure 7.12: Optional Two-Sensor Kit
–
Right Sensor
8.
Using a voltmeter, measure the voltage between the
ground (Pin 2) and signal (Pin 3) wires of the AHHC
sensor (A) at the back of the side frame. Ensure it is at
the low voltage limit for the combine. Refer to
Table
.
NOTE:
The wiring harness connector must be attached to the
sensor. Do
NOT
disconnect it.
9.
If the sensor voltage is not within the low and high
limits, or if the range between the low and high limits is
insufficient, adjust the voltage limits. Refer to
Voltage Limits: Two-Sensor System, page 163
10. Repeat at the opposite side.
Summary of Contents for FlexDraper FD1 Series
Page 2: ...FD1 Series FlexDraper Header Published June 2018...
Page 12: ......
Page 42: ......
Page 45: ...214685 33 Revision A Figure 4 6 Filler Cap 10 Install filler cap A SETTING UP FLOAT MODULE...
Page 72: ......
Page 116: ......
Page 166: ......
Page 336: ......
Page 350: ......
Page 353: ......