Figure 7.199: AHHC on Control Handle
3.
Press the AHHC control switch (A) on the control
handle to engage the AHHC. The header moves to the
current setpoint position.
Figure 7.200: Header Control Cluster
4.
Use the HEADER HEIGHT SETPOINT control dial (A)
as necessary to fine-tune the position.
Header In-Field Settings
NOTE:
Changes may have been made to the combine controls or display since this document was published. Refer to the
combine operator
’
s manual for updates.
Figure 7.201: Header Groups
1.
To view header group settings, touch HEADER icon (A)
on the right side of the home screen.
2.
The following information is displayed:
•
CURRENT POSITION of the header (B).
•
SETPOINT cut-off position (C) (indicated by red line)
•
HEADER symbol (D)
–
touch to adjust the setpoint
cut-off position using the scroll wheel on the right
side of the Tyton terminal.
•
CUT HEIGHT for the AHHC (E)
–
fine-tune with the
header height setpoint control dial on the header
control cluster.
•
HEADER WORKING WIDTH (F)
•
HEADER PITCH (G)