214685
189
Revision A
Figure 7.75: Case IH Combine Display
8.
Install REEL FORE-BACK (if applicable).
Figure 7.76: Case IH Combine Display
9.
Locate the HHC HEIGHT SENSITIVITY field (A), and
set as follows:
•
If using a two-sensor system:
Set HHC HEIGHT
SENSITIVITY to 250.
•
If using a single-sensor system:
Set HHC
HEIGHT SENSITIVITY to 180.
NOTE:
If hunting occurs during operation, decrease this setting
by 20 points at a time until hunting no longer occurs.
10. Set the HHC TILT SENSITIVITY (B) to 150. Increase or
decrease as desired.
Figure 7.77: Case IH Combine Display
11. Install FORE/AFT CONTROL and HDR FORE/AFT
TILT (if applicable).