214685
250
Revision A
Figure 7.209: John Deere Combine Display
10. Press the CAL button (A) to save the calibration of the
header. HDR H-UP appears on the monitor.
11. Raise the header 3 feet off the ground and press the
CAL button (A). EOC appears on the monitor.
12. Press the ENTER button (B) to save the calibration of
the header. Your AHHC is now calibrated.
NOTE:
If an error code appears during calibration, the sensor is
out of voltage range and will require adjustment. Refer
to
Checking Voltage Range from the Combine Cab
(John Deere 60 Series), page 246
NOTE:
After the calibration is complete, adjust combine
operation settings to ensure proper field operation.
NOTE:
If float was set heavier to complete the AHHC
calibration procedure, adjust to recommended
operating float after the calibration is complete.