6. CLEANING AND MAINTENANCE:

  

NOTE!

Always disconnect the unit from electrical outlet and never immerse the unit 

in water.

  

IMPORTANT!

 Do not open the heater tank cover right after use, as the cover might be very hot. 

Wait for approximate 10 minutes to allow it to completely cool.

Cleaning the parts:

1. Remove 

top 

cover.

2.  Remove furnish tank and pour out remaining water in drain.

3.  Open heater tank cover and pour out remaining water in heater tank.

4.  The furnish tank, top cover, mask, heater tank cover and suction tube should be cleaned with a 

mild detergent or commercially available disinfectant. Thoroughly rinse each part and allow to 
completely air dry.

5.  Wipe out heater tank with a soft, lint-free cloth.

Cleaning the main unit:

The main unit should be cleaned with a soft cloth moistened with a non-abrasive cleanser and water.

Maintenance:

If saline water has been used, use pure water to re-activate the unit for a few minutes to clean the 
nozzle.

7. TROUBLESHOOTING

Should any problems persist after you have made the following checks, return the unit to a nearest 
service center for examination and repair.

Condition

Checking points

Corrective actions

Lamp is not lit

Check whether power cord is well 
connected to the electrical outlet
Check whether power switch is at 
«ON» status

Firmly insert power cord

Press on power switch

No steam 
output

Check whether lamp is lit

Check if there is no water in heater or 
furnish tank

Check if the suction tube is bending

Check if the nozzles are blocked

Insert power cord and press on 
power switch

Fill water

Straighten the tube

Use attached nozzle pin to make 
them through

Water leakage

Check if the furnish tank is overfi lled

Check if the unit is tilted.

Pour out some water

Set fl at the unit

Steam 
leakage

Check if the heater tank cover is 
fi rmly locked

Check if nozzle is fi rmly locked

Lock the heater tank cover fi rmly

Lock the nozzle fi rmly

8. SPECIFICATIONS

Power:

230 V / 50 Hz 

Power consumption:

150 W

Heater tank capacity:

25 ml 

Furnish tank capacity:

60 ml

Water boiling time (waiting time):

Around 60 seconds

Treatment time:

7~10 minutes

Overheat auto-cutoff:

By thermo-fuse

Safety valves:

Dual valves on heater tank cover

Weight:

560 g

Dimension (L x W x H):

235 x 90 x 260 mm

9. WARRANTY

Warranty period is 2 years from the date of purchase. 
This warranty doesn’t cover any damages caused by improper using, packaging and the accessories 
supplied with the device and those parts subject to normal wear and tear.
The warranty does not apply to damage caused by using adapters not recommended by the B.Well 
company and the overvoltage.
When a manufacturing defect is revealed during the warranty period a faulty unit would be repaired 
or, if repairing is impossible, replaced with another one.
The manufacturer may change units partially or completely if necessary, without prior notice.
Manufacturing date is encoded in the SN number at the bottom of the device: two fi rst numbers are 
numbers of the week; two other numbers are last numbers of the year.
Manufacturing date of the spare parts, which can be bought separately from the device is encoded in 
the LOT number on the sticker: two fi rst numbers are numbers of the week, two other numbers are 
last numbers of the year.

10. SYMBOL INFORMATION

Distribuitor în România: Promed Solution MD SRL.

D

1. INTRODUCTION

Thank you for purchasing the Steam Inhaler. It is a compact device designed to relieve allergy, cold 
and some other respiratory disorders. With proper care and use, it will provide you with many years 
of reliable service.

We encourage you to thoroughly read this guidebook to learn about the features of this product. Any 
use of this product other than its intended use should always be avoided.

2. INTENDED USE

Nebulizers are used for inhalation therapy for asthma, chronic bronchitis, and other respiratory 
illnesses.

3. PRODUCT IDENTIFICATION

4. PRECAUTIONS

NOTE:

1.  Read all instructions carefully before use

2.  The following basic precautions are needed when using an electrical product:

Product cautions:

To avoid electrical shock:

  

Keep the unit away from water

  

Do not immerse the power cord or the unit in liquid

  

Do not use while bathing

  

Do not reach for a unit that has fallen into water - immediately unplug the unit.

3.  Never operate the unit if it has any damaged parts (including power cord), if it has been dropped 

or submersed in water. Promptly send it to a service center for examination and repair.

4.  Open top cover during operation is prohibited as it may cause severe injury.

5.  Disconnect the unit from the electrical outlet before cleaning, fi lling and after each use.

6.  Do not use other attachments unless recommended by manufacturer.

 Operating Cautions:

1.  Connect this product to an appropriate voltage outlet for your model.

2.  Do not run this product unattended.

3.  If the furnish tank is empty, do not attempt to operate the unit to avoid scald.

4.  Change the water in furnish tanks after each use.

5.  If any abnormality occurs, discontinue use immediately until the unit has been examined and 

repaired.

6.  Do not put your eyes on mask when steam is generated to avoid scald.

7.  If there is no steam generated from the 

heater tank, or water from furnish tank 
can not be sucked, shut off the unit and 
unplug it from the mains. Then carefully use 
the attached nozzle pin to insert into the 
nozzles of heater tank and/or furnish tank 
to make them through as shown on fi gure 1. 
Do not use other pins except the attached 
one to avoid damage to the unit.

8.  Do not block the vent holes on both sides 

of mask

9.  Always unplug the product immediately after use.

Storage Cautions:

1.  Do not store the unit under direct sunlight, high temperature or humidity.

2.  Keep the unit out of reach of small children.

3.  Always keep the unit unplugged while not in use.

4.  To store the unit for an extended period of time, open heater cover to keep the heater tank air dry.

Cleaning Cautions:

1.  Do not immerse the unit in water. It may damage the unit.

2.  Disconnect the unit from electrical outlet before cleaning.

3.  Clean all necessary parts after each use as instructed in this guidebook.

5. OPERATING YOUR STEAM NEBULIZER

It is important to clean the unit before the fi rst time of use and after each use. For details, see 
«Cleaning and Maintenance» in this guidebook.

1.  Place the unit on a rigid and fl at surface.

2.  Remove top cover from main body.

3.  Open heater cover by turning counterclockwise.

4.  Fill approximate 20ml pure water into heater tank with the attached 

cup. Do not overfi ll or the ventilation holes of heater tank will be 
blocked. 

NOTE!

 Do not fi ll saline water into heater tank.

5.  Replace heater cover. Make sure it is tightly placed to avoid leakage of 

steam.

6.  Fill approximate 80 ml pure water or saline water with attached cup 

into furnish tank as shown on fi gure 2.

NOTE!

If saline water is used, follow your physician’s instructions. Do 

not use saline water with salt’s concentration more than 7% 
as it might cause harm to your body.

7.  Replace top cover on main body. Make sure the suction tube is 

connected to the nozzle and inserted into furnish tank.

NOTE!

Avoid bending the suction tube to allow smooth fl ow of water 

into the nozzle.

8.  Place the mask on top cover.

9.  Plug power cord into an appropriate electrical outlet for your model. 

Make sure the power switch on power cord is at »OFF» status before 
plugging.

10. Press on power switch to begin treatment. The lamp at the bottom of 

unit will be lit.

11.  Adjust the slide lid for a comfortable treatment (See fi gure 3). Slide the 

lid down for smaller particle size of steam, which is more comfortable 
for the inhalation of nose. Slide the lid up for bigger particle size of 
steam, which is more comfortable for the inhalation of mouth. 

12.  After approx. 7 minutes, when the steam output becomes less and weaker, or the water in furnish 

tank is fi  nished, press power switch to shut off the unit. 

IMPORTANT!

 Shut off the unit within 3 minutes to avoid scald and overheating of the unit.

13.  Unplug the unit from electrical outlet.

14. For next use, please wait for 10 minutes to allow the unit to cool down.

EN

  

  

Instruction For Use

PRO-118

STEAM INHALER

READ INSTRUCTION BEFORE USE

DISPOSAL FOR SEPARATE COL-
LECTION

CLASS II EQUIPMENT

DO NOT USE THIS APPLIANCE 
NEAR WATER

CE MARK

SERIAL NUMBER

LOT NUMBER

ARTICLE NUMBER

MANUFACTURER’S NAME

KEEP DRY

OPERATING CONDITION, 
TEMPERATURE

STORAGE CONDITION,
TEMPERATURE

40

 5

-25

70

IM_PRO-

118_EN_AR_4019

 B.Well Swiss AG, Bahnhofstrasse 24,

9443, Widnau, Switzerland

www.bwell-swiss.ch

Reviews: