Keysight E5260/E5270 Programming Guide, Edition 4
2- 33
Remote Mode Functions
Trigger Function
Trigger Output
A trigger output operation example is shown in
. When the measurement
or source output setup is completed, the output trigger is sent through the port
specified by the TGP command. See
.
Figure 2-21
Trigger Output Example, Staircase Sweep Measurement, Negative Logic
Initial Settings
The following functions are available in the initial settings:
•
Trigger port: Ext Trig Out
•
Trigger type: Measurement Completion (type 1)
•
Commands for the trigger output: OS
Output Trigger
An edge trigger or a gate trigger will be sent when an operation is completed (see
). Initially, the negative edge trigger is sent.
Source Trigger
Delay
Delay time from when the source output setup is completed until an edge trigger is
sent or a gate trigger level is returned. The delay time is available for the Step
Output Setup Completion trigger (type 2). You can set the delay time value by using
the WT command.
OS/OSX
Commands
The command is used to send a trigger immediately from a trigger output terminal.
You can use the commands regardless of the trigger type.
: Measurement
TGP t,2,p,3
XE
TGP t,2,p,2
TGP t,2,p,1
TGP t,2,p,3
TGP t,2,p,2
TGP t,2,p,1
Gate trigger
Edge trigger
Source trigger delay
Hold time
Delay time
Source trigger delay
Step delay time
Step Measurement Completion
Step Output Setup Completion
Measurement Completion
Step Measurement Completion
Step Output Setup Completion
Measurement Completion
Summary of Contents for E5260 Series
Page 1: ...Keysight Technologies E5260 E5270 Series of Parametric Measurement Solutions Programming Guide...
Page 3: ...User s Guide B2900 9001x xxxx 201x Edition x...
Page 13: ...1 Programming Basics...
Page 63: ...2 Remote Mode Functions...
Page 108: ...2 46 Keysight E5260 E5270 Programming Guide Edition 4 Remote Mode Functions Initial Settings...
Page 109: ...3 Programming Examples...
Page 185: ...4 Command Reference...
Page 335: ...5 Error Messages...
Page 349: ......