Keysight E5260/E5270 Programming Guide, Edition 4
2- 41
Remote Mode Functions
Trigger Function
Trig In/Out Internal Circuit
The following figures show the trigger input/output circuits internally connected to
the Trig In/Out connectors.
Figure 2-24
Trigger Input Internal Circuit
Figure 2-25
Trigger Output Internal Circuit
Vcc
R1
R2
to trigger
input control
from Trig In (BNC)
Vcc=5 V
R1=215 ohm
R2=10 kohm
C1=1000 pF
C1
Vcc
R1
from trigger
output control
to Trig Out (BNC)
Vcc=5 V
R1=147 ohm
C1=1000 pF
74ABT245 or
equivalent