External Signal Exchange
85/121
Operating Manual dryve D1, ST-, DC-, EC/BLDC-Motor Control System - V2.4
6.4.6 State Machine Visualisation
Read
Statusword 6041h
bin
0000 0100 0100 0000
(MSB...LSB)
dec
04 64
hex
04 40
Read
Statusword 6041h
bin
0000 0110 0010 0001
dec
06 33
hex
06 21
Ready to
switch on?
Write
Controlword 6040h
bin
0000 0000 0000 0110
dec
00 06
hex
00 06
Shutdown
Switch on
disabled
Not ready
to switch on
Read
Statusword 6041h
bin
0000 0110 0100 0000
ec
06 64
hex
06 40
Bit 9 = High?
Set Digital Input 7 to status
high
Set Digital Input 7
Start
D1 boot up
D1 ready for further usage
e.g. Homing
Motor Current
applied
Read
Statusword 6041h
bin
0000 0110 0010 0111
dez
06 39
hex
06 27
Operation
enabled?
Write
Controlword 6040h
bin
0000 0000 0000 1111
dec
00 15
hex
00 0F
Enable Operation
Read
Statusword 6041h
bin
0000 0110 0010 0011
dec
06 35
hex
06 23
Switched on?
Write
Controlword 6040h
bin
0000 0000 0000 0111
dec
00 07
hex
00 07
Switch on
Yes
No
No
No
Automatic state transition
No