Initial Operation and User Interface
38/121
Operating Manual dryve D1, ST-, DC-, EC/BLDC-Motor Control System - V2.4
1.
Deactivate the dryve D1 by revoking the DI 7 "Enable" signal (external signal or switch on the "Inputs/Outputs" page)
8.
Activate a
“Feedback” by setting the switch to "ON"
9.
Select the used Feedback from the dropdown menu
10. If an index channel is available, you can activate it. The associated data sheet will tell you whether your encoder has
an index channel
a.
The index channel is activated by setting the switch to "ON"
11. Enter the impulses per shaft revolution into the "Impulses" field
b.
If the Feedback impulse count is not known, a
“Impulse Check” can be executed after further settings have
been done. The instructions are to be found at
5.4.5 Closed-Loop
The Closed-Loop control is able to reduce the motor's power consumption and its operating temperature significantly.
Due to a continuous position monitoring, step losses are not possible.
In the case of a Closed-Loop control, the maximum achievable velocities are lower than those of classical Open-Loop control.
The Closed-Loop control is only available with a connected encoder.
1.
Deactivate the dryve D1 by revoking the DI 7 "Enable" signal (external signal or switch on the "Inputs/Outputs" page)
2.
Activate
the “Closed-Loop” by setting the switch to "ON"
5.4.6 Self-Tuning
The Self-Tuning function determines the optimal motor current
“Controller Data” and stores them automatically on the
“Oscilloscope" page. These values are directly live.