Initial Operation and User Interface
30/121
Operating Manual dryve D1, ST-, DC-, EC/BLDC-Motor Control System - V2.4
5.2.1 Entering Parameters
The parameters entered are transferred directly, i.e. "live", to the control system. Additional confirmation, advance deactivation
of the "Enable" signal or a reboot of the control system is only necessary for parameters that are critical for operation.
Before the dryve D1 is rebooted, a period of 5 seconds must elapse before altered parameters are permanently saved.
Confirmation after Parameters entry
-
Motor Article Number
-
Motor Current
-
Boost Current
-
Holding Current
-
Step Mode
Deactivation of "Enable"
-
Motor Type
-
Step Angle
-
Pole Pairs
-
Gearbox Activation
-
Gearbox Ratio
-
Feedback Activation
-
Feedback Type
-
Feedback Impulses
-
Closed Loop
-
Brake Activation
-
Analogue Position Feedback Voltage Level AI2
-
Controller "Reboot"
Controller Reboot
-
"Automatic IP" or "Manual IP" Setting
-
IP Address
-
Subnetwork Mask
-
Standard Gateway
-
Host Name
-
"HTTPS" or "HTTP" Setting
The minimum and maximum values for each user interface parameter is found in the chapter