Installation
17/121
Operating Manual dryve D1, ST-, DC-, EC/BLDC-Motor Control System - V2.4
4.2 Electrical Installation
WARNING!
-
Danger of electrical voltage
-
Danger of electric arcs
Danger of injury and destruction of components.
Always turn off the power before disconnecting or making electrical connections in the system. Secure the power supply
against restart.
After switching the device off, wait at least 5 minutes. Check for the absence of voltage before working on the system.
Danger of electric arcs with improperly mounted electrical connections.
Wires connected to the dryve D1 must not have exposed wire ends without insulation. Check all connections for being
secured.
In the event of a fault, the motor housing can carry high currents. Connect the motor housing to the ground conductor via the
motor mounting components. In this regard, please observe the instructions in EN 60204-1.
CAUTION!
The maximum current of a Stepper Motor can be above the indicated rated current. The actual occurring current must be
considered for installation.
Any current setting are made at your own risk.