Initial Operation and User Interface
62/121
Operating Manual dryve D1, ST-, DC-, EC/BLDC-Motor Control System - V2.4
Anti-clockwise
5.8.2 Test Function
Created commands can be tested with the help of the "Start", "Stop" and "Quick-Stop" buttons.
1.
Select the "Inputs/Output" tab in the Navigation menu
2.
Set DI 7
“Enable
3.
Select the "Drive Profile" tab in the Navigation menu
4.
Mark the row to be executed by clicking in the number field in front of it
5.
Click on "Start" to execute the movement
6.
Click on "Stop" to stop the movement with a pre-set rate of deceleration
7.
Click on "Quick Stop" to stop the movement with the rate of deceleration previously set at "Motion Limits" on the
"Axis" page.
5.8.3 Position Adoption
The buttons under the parameterising table on the right-hand side of the screen can be used to manually move the motor
clockwise or anti-clockwise with the Jog Velocity specified under "Motion Limits".
With the "Teach" button, manually reached positions are adopted as the target position in a previously marked row of the
Determination of the direction of rotation
1.
View from drive shaft onto motor block
2.
Klick on “Clockwise” movement button
3.
Clockwise motor rotation
Clockwise