Initial Operation and User Interface
68/121
Operating Manual dryve D1, ST-, DC-, EC/BLDC-Motor Control System - V2.4
5.9 Oscilloscope and Controller Data
5.9.1 Oscilloscope Settings
The internal oscilloscope enables simultaneous observation of 4 channels over a period of 5 seconds. Each channel can
transfer one of eight different values.
•
Actual current (A)
•
Following Error
•
Speed (rpm)
•
Actual position
•
Desired position
•
Digital inputs
•
Analogue input 1
•
Analogue input 2
1.
Select the desired value with a drop-down menu
2.
Click on "Start" to start the oscilloscope
3.
Click on "Stop" to stop the recording
4.
Click on "Save" to download the data (in the form of a *.csv file) recorded by the oscilloscope. The file will
automatically be stored in the download folder of your browser
The axes corresponding to the respective channels are located at the left and right of the oscilloscope and are scaled
automatically. The Y axes are scalable manually by scrolling with the mouse wheel. All Y axes are scaled simultaneously with
the same factor. The automatic scaling is reactivated with a double click.