7 Alerts and Errors
Alerts
No.
Description
A
ler
t
1
0
A10 Temperature too high
The temperature of the power unit has risen above 85 °C.
In the event of a further temperature rise, please increase the cooling air flow, lower the ambient temperature,
reduce the acceleration or velocity or insert pauses between the movements.
A
ler
t
1
1
A11 Following Error
50% of the allowed Following Error reached
If value falls under 50% again the alert will be reset automatically after 1 minute.
Please check the mechanical construction if executed correctly, decrease the acceleration, increase the “Motor
Current”, the “Boost Current” or reduce the load
A
ler
t
1
8
A18 Position window
The position window has been left before the Positioning Time has been lapsed.
Please check the load, the forces applied to the motor or adopt the positioning window
Errors
No.
Description
E
rr
o
r
1
E01 Configuration
Please check the configuration. Incorrect parameter combination
E
rr
o
r
2
E02 Motor Over-current
Possible short circuit of the motor phases or incorrect current control parameter
If EC/BLDC with Brake Resistor is being used:
Resistance value attached to X5.4 and X5.5 too low
E
rr
o
r
3
E03 Encoder Over-current
Electric load at terminals X6:1 is too high
Please check all electrical connections
E
rr
o
r
4
E04 10 V Output Over-current
Electric load at terminal X4:1 is too high
Please check all electrical connections
E
rr
o
r
5
E05 I/O Supply
There is no or too little voltage at terminal X2:11-12
Please check if a permissible voltage from 5 to 24 V is applied to the terminal
E
rr
o
r
6
E06 Logic Supply Low
Voltage at terminal X1:3-2 is too low
Please check if a permissible voltage from 5 to 24 V is applied to the terminal
E
rr
o
r
7
E07 Logic Supply High
Voltage at terminal X1:3-2 too high
Please check if a permissible voltage from 5 to 24 V is applied to the terminal