External Signal Exchange
87/121
Operating Manual dryve D1, ST-, DC-, EC/BLDC-Motor Control System - V2.4
6.4.8 Controlword
The Controlword can be used to trigger changes to the dryve D1
Bit assignment Controlword 6040h
Bit Description
Different meaning "Mode Specific"
Homing
Profile Position
Profile Velocity
0
Switch On
-
-
-
1
Enable Voltage
-
-
-
2
Quick Stop
-
-
-
3
Enable Operation
-
-
-
4
Mode Specific
0: Homing Blocked
0: No Start Signal
-
1: Homing Start
1: Start of Movement (0 > 1)
-
5
Mode Specific
-
-
-
-
1: Instant new parameter
adoption
-
6
Mode Specific
-
0: Absolute Positioning
-
-
1: Relative Positioning
7
Fault Reset
-
-
-
1: Error Reset
1: Error Reset
1: Error Reset
8
Halt
0: Enable Bit 4
0: Movement Enabled
-
1: Not enabled/Stop
1: Not enabled/Stop
-
9
Mode Specific
-
0: Point to point movement
-
-
1: Position override
-
10
Reserved
-
-
-
11
Manufacturer Specific
-
-
-
12
Manufacturer Specific
-
-
-
13
Manufacturer Specific
-
-
-
14
Manufacturer Specific
-
-
-
15
Manufacturer Specific
-
-
-
Note
After
passing through the State Machine successfully and obtaining the state “Operation enabled” the Bits 0, 1, 2 and 3 must
be sent with each Controlword telegram to maintain the state “Operation enabled”
6.4.9 Parameter Entry
All parameters are to be entered without dimensions. Parameters that need a dimension due to their nature, are handled in
detail in the respective object description.
When using “Relative Positioning” (Bit 6 Controlword 6040h set to 1) the values inserted into object 607Ah „Target Position“ can
be positive and negative