Overview of input values
119/121
Operating Manual dryve D1, ST-, DC-, EC/BLDC-Motor Control System - V2.4
Page
Group
Subitem 1
Subitem 2
Evaluated input
Axis
Absolute Feedback
AI 1 Min. Target Value (V)
-10 V to 10 V
AI 1 Max. Target Value (V)
-10 V to 10 V
AI 1 Dead Band Zero Value
From 0 to 1 in 0,001 V steps
AI 1 Dead Band Input Signal
From 0 to 1 in 0,001 V steps
AI 1 Filter
from 0 to 65.535
AI 2 Min. Absolute Value (V)
-10 V to 10 V
AI 2 Max. Absolute Value (V)
-10 V to 10 V
Communication
Ethernet TCP/IP
IP Address
from 0.0.0.1 to 254.254.254.254
Subnetwork Mask
from 0.0.0.1 to 254.254.254.254
Standard Gateway
from 0.0.0.1 to 254.254.254.254
Host Name
40 characters
Bus Systems
CANopen
Node ID
from 1 to 127
Modbus TCP Gateway
Port
from 0 to 65535
Unit Identifier
from 1 to 255
Drive Profile
Binary
Mode
ABS
0 to Motion Limit
REL
from 0 to 1,000,000
APS
0 to Motion Limit
Acceleration
0 to Motion Limit
Velocity
0 to Motion Limit
Deceleration
0 to Motion Limit
Pause
0 ms to 100,000.000 ms
Next
from 0 to 32
Tipp/Teach
Mode
ABS
0 to Motion Limit
Acceleration
0 to Motion Limit
Velocity
0 to Motion Limit
Deceleration
0 to Motion Limit