Initial Operation and User Interface
72/121
Operating Manual dryve D1, ST-, DC-, EC/BLDC-Motor Control System - V2.4
If the carriage moves very slowly or hardly at all, gradually increase the
“Jog Velocity” on the "Axis" page, until a
movement is clearly visible. If the carriage moves too quickly, reduce the
“Jog Velocity”
25. Use the Position Adoption buttons to move the carriage as far as possible. Measure the distance of the carriage to
one end of the axis again.
This value is called XM2.
(In this example: XM2 = 200 mm)
Read the new
“Actual Position” in the status window.
This value is called XS2.
(In this example XS2 = 160 mm)
26. Now calculate the correct
“Feed Rate” with the following formula:
𝐹𝑒𝑒𝑑 𝑅𝑎𝑡𝑒 =
|𝑋𝑀2 − 𝑋𝑀1|
|𝑋𝑆2 − 𝑋𝑆1|
∗ 70 [𝑚𝑚]
In this example:
𝐹𝑒𝑒𝑑 𝑅𝑎𝑡𝑒 =
|200 − 100|
|160 − 80|
∗ 70 [𝑚𝑚] = 87,50 [𝑚𝑚]
27. Enter the new
“Feed Rate” at "Axis".