External Signal Exchange
77/121
Operating Manual dryve D1, ST-, DC-, EC/BLDC-Motor Control System - V2.4
Summary Binary Movement Selection
The table shows which Digital Inputs must be switched to select the desired positioning movement.
If you use the Inverting function (switch for the respective input changed from "H" (High) to "L" (Low) on the "Inputs/Outputs"
page), this input will be interpreted as active if it is pulled to ground.
Movement No.
DI 5
DI 4
DI 3
DI 2
DI 1
1
0
0
0
0
0
2
0
0
0
0
1
3
0
0
0
1
0
4
0
0
0
1
1
5
0
0
1
0
0
6
0
0
1
0
1
7
0
0
1
1
0
8
0
0
1
1
1
9
0
1
0
0
0
10
0
1
0
0
1
11
0
1
0
1
0
12
0
1
0
1
1
13
0
1
1
0
0
14
0
1
1
0
1
15
0
1
1
1
0
16
0
1
1
1
1
17
1
0
0
0
0
18
1
0
0
0
1
19
1
0
0
1
0
20
1
0
0
1
1
21
1
0
1
0
0
22
1
0
1
0
1
23
1
0
1
1
0
24
1
0
1
1
1
25
1
1
0
0
0
26
1
1
0
0
1
27
1
1
0
1
0
28
1
1
0
1
1
29
1
1
1
0
0
30
1
1
1
0
1
31
1
1
1
1
0
32
1
1
1
1
1
A "1" corresponds to a voltage between 5 and 24 V. A "0" corresponds to 0 V (ground).
If automated motion sequences have been set at the
“Drive Profile”, they are executed after the positioning has been
completed.