1-63
General Information
Specifications
Alarm indication ATM Layer (All
rates): Loss of cell sync, Selected cell
not received, VP alarm, VC alarm.
Alarm seconds Physical Layer:
2.048 Mb/s, 34.368 Mb/s, 139.264
Mb/s: Power Loss, Loss of Signal,
Loss of Frame, AIS, FERF, RAI.
155.52 Mb/s, 622.08 Mb/s: Loss of
power, Loss of Signal, Loss of frame,
Out of frame, Loss of pointer, MS and
path AIS, K1/K2 change, MS and path
FERF, H4 multiframe, TU loss of
pointer, TU path AIS, TU path FERF.
Alarm seconds ATM Layer (All
rates): Power Loss, Loss of cell sync,
Selected cell not received, Congestion
experienced, Test cell loss, Pattern
Loss, PM OAM loss, VP AIS, VP
FERF, VP LOC, VC AIS, VC FERF,
VC LOC.
ETSI/ANSI Internal Transmitter Clock Rates (Option UKZ)
Rates and Frequency
DS1: 1.544Mb/s:
DS3: 44.736Mb/s
E1: 2.048Mb/s
E3: 34.368Mb/s
Accuracy: DS1
± 0.7
ppm
@
25
C
DS3, E1 and E3 DS1
± 0.5
ppm
@
25
C
Temperature stability at all rates:
≤
3ppm (0 to +50C)
Ageing Stability at all rates:
≤
1ppm/year
ETSI/ANSI Transmitter Output Level and Waveshape (Option UKZ
Rate
Frequency
Level
Waveshape
DSX-1
1.544Mb/s
3.0V 20%
Fits mask T1.102-1993
DS1-LO
1.544Mb/s
As DSX-1 with 655' ABAM
Cable
DS3-HI
44.736Mb/s
0.9V pk (nominal)
DSX-3
44.736Mb/s
560mV pk (nominal)
Fits mask T1.102-1993
DS3-900
44.736Mb/s
330mV pk (nominal)
E1 (bal)
2.048Mb/s
3.00V 10%
As per ITU rec G703
E1 (unbal)
2.048Mb/s
2.37V 10%
As per ITU rec G703
E3
34.368Mb/s
1.0V 10%
As per ITU rec G703
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Page 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...