The following procedure should be used when fitting any new Module into the HP
37717C.
C AU T I O N
This procedure should only be carried out by qualified Service Personnel.
C AU T I O N
Anti-static precautions must be observed at all times. - Use the anti-static wrist-strap
provided in this kit if an anti-static work-area conforming to Corporate Standard
741.808 is unavailable.
C AU T I O N
Read the anti-static documentation at the end of this procedure.
1
Switch off the instrument and disconnect the power cord.
2
Remove the rear panel feet.
Jitter Tx
UHK, A3K [A3Q],
140 [141]
If Mult O/P fitted, immediately to the
right of this. If Mult O/P not fitted,
immediately to the right of SDH. If SDH
and Mult. O/P not fitted immediately to
right of Optics.
Jitter Rx
UHN [US9], A1M
[A1Q],, A1N [A1R],
A1P [A1S], A3L
[A3M], A3V [A3W],
A3N [A3P]
If Binary Interfaces (UH3) fitted
Immediately to the right of it. If UH3 not
fitted immediately to right of PDH RX. If
UH3 and PDH not fitted immediately to
right of SDH.
Blanking Plates
37714-00013
(single) 37714-
00014 (double)
Blanking Plates should be fitted at the
rear (CPU end) to fill in any gaps left after
fitting all required modules.
Table B-2
Configurations for the HP 37717C Modules
Module Description
Option Numbers
Fitting Instructions
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Page 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...