3-165
Performance Tests
Jitter Receiver STM-1/STM-4 Optical Interface (Options A1P, [A1S], A3N
[A3P])
Jitter Receiver STM-1/STM-4 Optical Interface
(Options A1P, [A1S], A3N [A3P])
N OT E
This test requires other modules to be fitted - see Appendix B.
Specification
Description
The Jitter Receiver optical sensitivity is verified by attenuating the transmitter
outputs and checking for no errors in back to back mode at both STM-1 and STM-4
rates.
Equipment Required
Wavelength
1200 nm to 1600 nm
Maximum Input Power
-8 dBm (for BER of 1.0E
-10
)
Line Coding
NRZ
Dynamic Range
18 dB minimum
Sensitivity
-26 dBm Minimum (wavelength=1300nm,
Modulation=100%, Data=2
23
-1, BER=1.0E
-10
)
Power Meter
: HP 8153A
Power Meter Sensor Module
: HP 81536A
FC/PC Connector Interface
: HP 81000FI (Qty. 4)
Optical Attenuator
: HP 8157A
Optical Cables (Qty. 2)
: HP 11871A