3-65
Performance Tests
External 2Mb/s Demux (Options UKL, [USC])
7. Press
on the HP 37717C
and set the
display as shown opposite.
8. Press
on the Test Set.
Press
PDH on the Test Set and
ensure that the Bit Error Count and Code
Error Count are both zero.
9. Press
error add key on the
Test Set and ensure the Bit Error count
increments by one each time the key is
pressed.
10. Disconnect the Drop Port from the Test Set and connect it to the oscilloscope
Input 1 via a "T" connector and a 75
Ω
termination. Set the oscilloscope termination
to 1M
Ω
and press
.
11. Adjust the Oscilloscope Timebase and Delay to position the positive peak pulse
amplitude at mid-pulse-width point in the centre of the screen.
12. Measure the peak pulse amplitude at mid-pulse-width using the Oscilloscope and
verify that this is between 2.133V and 2.607V.
13. Select the 2Mb G.703 mask on the oscilloscope and store it on the display.
14. Press SHIFT
on the oscilloscope to automatically align the pulse
to the mask. Verify that the pulse falls within the mask as shown in Figure 3-30.
Figure 3-29
2 Mb/s Pulse Mask
RECEIVE
STRUCTURED SETTINGS
RUN/STOP
RESULTS
SINGLE
AUTOSCALE
AUTOSCALE
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Page 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...