3-194
Performance Tests
ETSI/ANSI Receiver Monitor Levels (Option UKZ)
ETSI/ANSI Receiver Monitor Levels (Option UKZ)
Specifications
Description
The Receiver Monitor capability is checked by looping the transmitter output to re-
ceiver input through a series of matching pads and selectable fixed attenuators. The
total attenuation of this loop is calculated to be the same as the selected Monitor at-
tenuation. A BER measurement is run and a check made for no errors in the results
page for each selection of Bit Rate and monitor attenuation.
Bit Rate
Cable Loss Accommodation (Monitor
mode)
Monitor Gain
2.048Mb/s
(Unbalanced Mode)
Selectable OFF or Automatic (Up to 6dB for
root f cable @ half-bit rate).
Selectable 20dB, 26dB
or 30dB
2.048Mb/s
(Balanced Mode)
Selectable OFF or Automatic - Up to 6dB
(20dB selected) or 3dB (26 or 30dB selected)
for root f cable @ half-bit rate .
Selectable 20dB, 26dB
or 30dB
34.368Mb/s
Selectable OFF or Automatic (Up to 12dB
for root f cable @ half-bit rate)
Selectable 20dB or26dB
1.544Mb/s (DS1)
Signal range from DS1-LO to DSX-1
Selectable 20dB, 26dB
or 30dB
44.736Mb/s (DS3) Selectable OFF or Automatic (Up to 900 feet
of type 728A Cable (root f)
Selectable 20dB or26dB
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Page 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...