3-235
Performance Tests
ETSI/ANSI Receiver Monitor Levels (Option 110)
2.048 Mb/s
3. Press
and set up the
display as shown
opposite.
4. Press
and set up the
display as shown opposite.
5. Press
.
Press
to start the
measurement.
6. Ensure that NO TROUBLE is
displayed on the
display
7. After 30 seconds. Press
to
stop the measurement.
8. Press
and select EQUALIZATION [ON] GAIN [20 dB].
9. Connect Cable Simulator #1 between the PDH OUT Port and the Matching Pad.
10. Press
. Press
to start the
measurement.
11. Ensure that NO TROUBLE is displayed on the
display after 30
seconds. Press
to stop the measurement.
12. Connect the second 6dB Fixed Attenuator in the signal path to give a total path
attenuation of 26.8dB (7.6+3+6+6+4.2).
13. Press
and set MONITOR LEVEL [26dB].
14. Press
;
. Press
to start the
measurement.
15. Ensure that NO TROUBLE is displayed on the
display after 30
seconds. Press
to stop the measurement.
TRANSMIT
MAIN SETTINGS
RECEIVE
MAIN
SETTINGS
RESULTS
TROUBLE SCAN
RUN/STOP
RESULTS
RUN/STOP
RECEIVE
RESULTS
TROUBLE SCAN
RUN/STOP
RESULTS
RUN/STOP
RECEIVE
RESULTS
TROUBLE SCAN
RUN/STOP
RESULTS
RUN/STOP
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...