3-173
Performance Tests
PDH Binary Interfaces (Option UH3, [US7])
Unstructured PDH Option UKK [USB]
3. Press
and set up the display as
shown opposite.
4. Press
and set up the display as shown opposite.
5. Set the Signal Generator to Frequency -
700 kHz, Output Level - 500 mV and
connect to the EXT CLOCK input port of
the binary interfaces module.
6. Connect the HP 37717C binary
CLOCK O/P to the oscilloscope via the
75
Ω
/50
Ω
matching pad and check that the
mark/space ratio of the displayed clock
waveform is between 60/40 and 40/60.
7. Press
and set up the display as
shown opposite.
TRANSMIT
PDH
MAIN
SETTINGS
TRANSMIT
PDH
BINARY
TRANSMIT
PDH
MAIN
SETTINGS
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Page 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...