
3-215
Performance Tests
STM-1/STS-3 Receiver Monitor Input (Options A1T, A1U, A3R, [A3S],
120)
STM-1/STS-3 Receiver Monitor Input (Options A1T,
A1U, A3R, [A3S], 120)
Specification
Description
An attenuator and special cable attenuator are inserted between the STS-3 OUT port
and the STS-3 IN port. The Receiver monitor mode is verified by attenuating the
signal by 20 dB and checking for error-free operation.
Equipment Required
Procedure
1. Recall the HP 37717C DEFAULT SETTINGS as shown on 3-2.
2. Select TRANSMITTER OUTPUT [SDH] or [SONET] and RECEIVER INPUT
[SDH] or [SONET].
3. Connect up the equipment as shown in Figure 3-65.
Receiver Monitor Mode
Selectable 20 dB and 26 dB of flat gain
12 dB equalization at 1/2 Bit Rate
3 dB Attenuator (N-type)
: HP 8491A Option 003
6 dB Attenuator (N-type) (2 off)
: HP 8491A Option 006
75/50
Ω
Matching Pad (N-type)
: HP 11852B (Qty 2)
N-type (f) to BNC (f) Adaptor
: HP 1250-1536 (Qty 2)
N-type (m) to N-type (f)Adaptor
: HP 1250-1475
Cable Attenuator (70 m)
: HP 8120-0049
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Page 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...