3-43
Performance Tests
PDH Receiver Equalization (Options UKK, [USB], UKJ, [USA], UKL,
[USC], UKN, [USE])
PDH Receiver Equalization (Options UKK, [USB], UKJ,
[USA], UKL, [USC], UKN, [USE])
Specifications
Description
The PDH receiver equalization is checked using a Synthesizer set for a sinewave at
half the data rate. This sinewave corresponds to a ternary all ones signal and the HP
37717C receiver should sync up with no errors if PATTERN [ALL ONES] is
selected. The amplitude of the synthesizer signal is set to the specified maximum
loss for each bit rate. At that amplitude no errors should result.
Equipment Required
Bit Rate
Option
Equalization at 1/2 Bit Rate
704 kb/s
UKK, [USB]
6dB
2.048 Mb/s
UKK, [USB], UKJ, [USA],
UKL, [USC], UKN, [USE]
6dB
8.448 Mb/s
UKK, [USB], UKJ, [USA],
UKL, [USC], UKN, [USE]
6dB
34.368 Mb/s
UKK, [USB], UKJ, [USA],
UKL, [USC], UKN, [USE]
12dB
139.264 Mb/s
UKK, [USB], UKJ, [USA],
UKL, [USC], UKN, [USE]
12dB
Synthesizer
: HP 3335A option 001
Oscilloscope
: HP 54503A
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Page 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...