3-250
Performance Tests
Performance Test Record
PDH Frequency Measurement and
Looped Clock
3-75
Step 8:
Frequency
2.047986 MHz
2.048014 MHz
Step 9:
Offset (0 ppm)
-7 ppm
+7 ppm
Step 10:
Frequency
2.048190 MHz
2.048219 MHz
Step 11:
Offset (+100 ppm)
+93 ppm
+107 ppm
Step 12:
Frequency
2.047781 MHz
2.047810 MHz
Step 13:
Offset (-100 ppm)
-93 ppm
-107 ppm
Frequency Counter
Pass/Fail
Step 14:
704 kb/s (0 ppm) UKK
only
-7 ppm
+7 ppm
704 kb/s (-100 ppm)
UKK only
-93 ppm
-107 ppm
704 kb/s (+100 ppm)
UKK only
+93 ppm
+107 ppm
:
Offset 8 Mb/s (0 ppm)
-7 ppm
+7 ppm
Offset 8 Mb/s
(-100 ppm)
-93 ppm
-107 ppm
Offset 8 Mb/s
(+100 ppm)
+93 ppm
+107 ppm
Offset 34 Mb/s
(0 ppm)
-7 ppm
+7 ppm
Offset 34 Mb/s
(-100 ppm)
-93 ppm
-107 ppm
Offset 34 Mb/s
(+100 ppm)
+93 ppm
+107 ppm
Offset 140 Mb/s
(0 ppm)
-7 ppm
+7 ppm
Offset 140 Mb/s
(-100 ppm)
-93 ppm
-107 ppm
Table 11
Performance Test Record
Page
No.
Test Description
Result
Min Actual Max
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Page 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...