3-22
Performance Tests
Multiple PDH Transmitter Outputs (Options UHC, [US6])
Multiple PDH Transmitter Outputs (Options UHC,
[US6])
N OT E
A PDH Option must be fitted for this option to operate - see Appendix B.
Specifications
Pulse Shape: As per ITU Rec. G.703
Additional Outputs Delay
N OT E
704 kb/s is only valid when Option UKK, [USB] is fitted.
Description
This test verifies that the 3 additional PDH transmitter outputs meet ITU pulse shape
and level specifications for all rates. Each PDH Signal Out Port is connected to a
Digitizing Oscilloscope terminated in 75
Ω
and the waveform is checked for
required amplitude and duty cycle at the nominal mid-points.
Pulse Amplitude:
704 kb/s
2.37V
±
10%
2 Mb/s
2.37V
±
10%
8 Mb/s
2.37V
±
10%
34 Mb/s
1.00V
±
10%
140 Mb/s
0.50V
±
10%
704 kb/s, 2, 8 and 34 Mb/s
Signal Out 2
4 bits
704 kb/s, 2, 8 and 34 Mb/s
Signal Out 3
8 bits
704 kb/s, 2, 8 and 34 Mb/s
Signal Out 4
12 bits
140 Mb/s
Signal Out 2, 3, 4
No delay
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Page 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...