3-199
Performance Tests
ETSI/ANSI Receiver Monitor Levels (Option UKZ)
10. Press RESULTS [TROUBLE SCAN] , then RUN/STOP key to start the
measurement.
11. Ensure that NO TROUBLE is displayed on the RESULTS page after 30 seconds.
12. Press RUN/STOP key to stop the measurement.
DS1 20dB Monitor
1. Recall the HP 37717C Default Settings as shown on 3-2.
2. Select the HP 37717C TRANSMIT
page, select PHYSICAL LAYER and set
as follows;
3. Select the HP 37717C RECEIVE
page, select PHYSICAL LAYER and set
as follows;
4. Connect the equipment as shown in Figure 3-57 below, but use the Balanced DS1
output and input ports on the HP 37717C connected via two 110/75 ohm bal to Unbal
converters.
5. Press RESULTS [TROUBLE SCAN] , then RUN/STOP key to start the
measurement.
6. Ensure that NO TROUBLE is displayed on the RESULTS page after 30 seconds.
7. Press RUN/STOP key to stop the measurement.