3-88
Performance Tests
STM-1 Transmitter Output Waveshape (Options US1, [US5], A1T, [A1U],
A3R [A3S], 120)
8. Adjust the Oscilloscope controls to display the waveform as shown in Figure 3-
37, STM-1 All Zeros Pattern Example.
9. Use the Oscilloscope PRINT function to obtain a printout of the STM-1
waveform on the external printer.
10. Ensure this printout fits the STM-1 Mask of Figure 3-38.
N OT E
If a mylar mask is not available, the figure shown may be traced or photocopied onto
a transparency.
Figure 3-37
STM-1 All Zeros Pattern
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...