3-160
Performance Tests
Jitter Receiver STM-1E Monitor Input (Options A1M [A1Q], A1N [A1R],
A1P [A1S], A3L [A3M], A3V [A3W], A3N [A3P])
Jitter Receiver STM-1E Monitor Input (Options A1M
[A1Q], A1N [A1R], A1P [A1S], A3L [A3M], A3V [A3W],
A3N [A3P])
N OT E
An SDH Option must be fitted for this option to operate - see Appendix B.
Specification
Description
A fixed attenuator and a special cable attenuator are inserted between the STM-1
OUT port and the Jitter Receiver STM-1 IN port. The STM-1E Jitter Receiver
monitor mode is verified by attenuating the signal by 20dB, along with the cable
attenuator, and checking for error-free operation.
Equipment Required
Procedure
1. Recall the HP 37717C DEFAULT SETTINGS as shown on 3-2.
2. Select TRANSMITTER OUTPUT [SDH] and RECEIVER INPUT [SDH
JITTER].
Receiver Monitor Mode
20 dB of flat gain, 12dB Equalization at 1/2 Bit Rate
3 dB Attenuator (N-type)
: HP 8491A Option 003
6 dB Attenuator (N-type)
: HP 8491A Option 006 (Qty 2)
75/50
Ω
Matching Pad (N-type)
: HP 11852B (Qty 2)
N-type (f) to BNC (f) Adaptor
: HP 1250-1536 (Qty 2)
N-type (m) to N-type (f)Adaptor
: HP 1250-1475
Cable Attenuator (70m)
: HP 8120-0049
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Page 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...