1-34
General Information
Specifications
STM-1 OPTICAL INTERFACE:
Option UH1.
Rate: 155.52 Mb/s
Line code: NRZ
Connectors: Adaptors to which a range
of interfaces can be attached.
Transmit:
Wavelength: 1280 - 1330 nm
Fibre power output: nominal -9 dBm
Safety classification: Class 1, FDA 21
CFR Ch.1 1040.10 and EN 60825
Receive:
Wavelength: 1200 - 1600 nm
Sensitivity: -28 dB minimum (with
1300 nm wavelength, 100% modulation
depth, BER of 10
-10
and 2
23
PRBS)
Maximum input power: -8 dBm (for
BER of 10
-10
)
Alarms detected: Loss of optical
signal.
STM-1/STM-4 OPTICAL
INTERFACE: Option UH2.
Rate: 155.52 Mb/s, 622.08 Mb/s
Line code: NRZ
Connectors: Adaptors to which a range
of interfaces can be attached.
Transmit:
Wavelength: 1280 - 1330 nm
Fibre power output: nominal -10 dBm
Safety classification: Class 1, FDA 21
CFR Ch.1 1040.10 and EN 60825
Receive:
Wavelength: 1200 - 1600 nm
Sensitivity: -26 dB minimum (with
1300 nm wavelength, 100% modulation
depth, BER of 10
-10
and 2
23
PRBS)
Maximum input power: -8 dBm (for
BER of 10
-10
)
Alarms detected: Loss of optical
signal.
Background STM-1 overhead:
A1,A2 contains pattern F628
(hexadecimal)
C1 - 00000001 to 00000100
Unused C1 bytes - AA (hexadecimal)
B1 - Correct BIP-8 parity
H1,H2 - 6A and 0A (hexadecimal),
Y=93 (hexadecimal)
B2 - Correct BIP-24 parity
B3 - Correct BIP-8 parity
H4 is transmitted as all zeroes unless a
TU-12 payload is selected, in which
case the reduced H4 sequence defined
in ITU-T Rec. G.709 is transmitted.
All other overhead bytes are
transmitted as all zero’s.
STM-1/STM-4 OPTICAL
INTERFACE: Option URU.
Rate: 155.52 Mb/s, 622.08 Mb/s
Line code: NRZ
Connectors: Adaptors to which a range
of interfaces can be attached.
Transmit:
Wavelength: 1520 - 1565 nm
Fibre power output: nominal -1 dBm
Safety classification: Class 1, FDA 21
CFR Ch.1 1040.10 and EN 60825
Receive:
Wavelength: 1200 - 1600 nm
Sensitivity: -26 dB minimum (with
1300 nm wavelength, 100% modulation
depth, BER of 10
-10
and 2
23
PRBS)
Maximum input power: -8 dBm (for
BER of 10
-10
)
Alarms detected: Loss of optical
signal.
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Page 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...