3-70
Performance Tests
PDH Receiver Monitor Levels (Special Option 808)
2.048 Mb/s
9. Select SIGNAL [2 Mb/s] on the
display.
10. Set the Synthesizer to: FREQUENCY - 1024 KHz sinewave AMPLITUDE -
237.5 mV pk-pk (26dB down) as measured on the oscilloscope.
11. Press
and verify that no errors are displayed at the end of the test
period (5 seconds).
8.448 Mb/s
12. Select SIGNAL [8 Mb/s] on the
display.
13. Set the Synthesizer to: FREQUENCY - 4224 KHz sinewave AMPLITUDE -
237.5 mV pk-pk (26dB down) as measured on the oscilloscope.
14. Press
and verify that no errors are displayed at the end of the test
period (5 seconds).
34.368 Mb/s
15. Select SIGNAL [34 Mb/s] on the
display.
16. Set the Synthesizer to: FREQUENCY - 17184 KHz sinewave AMPLITUDE - 71
mV pk-pk (29dB down) as measured on the oscilloscope.
17. Press
and verify that no errors are displayed at the end of the test
period (5 seconds).
139.264 Mb/s
18. Select SIGNAL [140 Mb/s] on the
display.
19. Set the Synthesizer to: FREQUENCY - 69632 KHz sinewave AMPLITUDE - 50
mV pk-pk (26dB down) as measured on the oscilloscope.
20. Press
and verify that no errors are displayed at the end of the test
period (5 seconds).
RECEIVE
RUN/STOP
RECEIVE
RUN/STOP
RECEIVE
RUN/STOP
RECEIVE
RUN/STOP
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Page 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...