3-35
Performance Tests
PDH Frame Analysis (Options UKK, [USB])
PDH Frame Analysis (Options UKK, [USB])
Specifications
Equipment Required
Frame Generator : HP 37729A
Description
An HP 37729A Frame Generator is used to generate the appropriate Frame
Alignment Signals (FAS) which are used to test the HP 37717C In-Service Analysis
at all bit rates with this capability.
N OT E
If the HP 37729A is not available, a HP 37714/17A with Option UKJ, [USA] may be
substituted.
140 Mb/s
Frame Loss - 4 consecutive incorrect FAS words.
Frame Gain - 3 consecutive correct FAS words (1111010000).
34 Mb/s
Frame Loss - 4 consecutive incorrect FAS words.
Frame Gain - 3 consecutive correct FAS words (1111010000).
8 Mb/s
Frame Loss - 4 consecutive incorrect FAS words.
Frame Gain - 3 consecutive correct FAS words (1111010000).
2 Mb/s
Frame Loss - 3 consecutive incorrect FAS words or NFAS words.
Frame Gain - 1 correct sequence of FAS - NFAS - FAS words.
2 Mb/s CRC
MultiFrame Loss - 3 out of 4 MultiFrame sequences in error
MultiFrame Gain - 2 out of 4 MultiFrame sequences are correct.
2 Mb/s CAS
MultiFrame Loss - 2 consecutive MultiFrame patterns in error.
MultiFrame Gain - 1 correct MultiFrame pattern is correct.
Summary of Contents for 37717C
Page 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Page 5: ...2 ...
Page 21: ...xviii Contents ...
Page 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Page 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Page 375: ...3 266 Performance Tests Performance Test Record ...
Page 379: ...4 4 Installation Current Previous Terminology ...
Page 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Page 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...